Installation points of FRP cable ladder accessories

Installation points of FRP cable ladder accessories

  • Categories:news
  • Author:
  • Origin:
  • Time of issue:2022-11-01
  • Views:0

(Summary description)To install FRP cable ladder accessories, it is necessary to compile data application plans according to the standard types of description requirements, site survey records and construction plans, including straight sections, bends, bridge accessories, supports, and hangers of various standard cable trays.

Installation points of FRP cable ladder accessories

(Summary description)To install FRP cable ladder accessories, it is necessary to compile data application plans according to the standard types of description requirements, site survey records and construction plans, including straight sections, bends, bridge accessories, supports, and hangers of various standard cable trays.

  • Categories:news
  • Author:
  • Origin:
  • Time of issue:2022-11-01
  • Views:0
Information

To install FRP cable ladder accessories, it is necessary to compile data application plans according to the standard types of description requirements, site survey records and construction plans, including straight sections, bends, bridge accessories, supports, and hangers of various standard cable trays. ladder accessories to check.

Wholesale FRP cable ladder accessories factory
There are five main points in the FRP cable ladder accessories installation guide:
1. When the height of the set bridge is 50, 100, 6 connection holes need to be reserved at each end, and when the height is 150, 200, 12 connection holes need to be reserved at each end.​​
2. Support spacing: The support spacing should be less than or equal to the allowable load and support span of the load curve.​​
3. Bridge width: In addition to determining the width of FRP cable ladder accessories according to various data, a certain space should be reserved to ensure that there is a place for adding cables in the future.​​
4. Separated laying: When there are few power cables and control cables, they can be installed in the same bridge, but the power cables and control cables must be laid separately with a partition in the middle.
5. Cable fixing: The FRP cable ladder accessories manufacturer tells you that when the wire tray is laid horizontally, the connection between the trays should be set at 1/4 of the span as far as possible. The fixed spacing of cables running horizontally and vertically is different, 2 meters and 1.5 meters, respectively.

Keyword:

Scan the QR code to read on your phone

这是描述信息

Jiangsu Fiber Composite Co., Ltd. 

Tel:+86 -025-86798609

MP:+86-139-0518-7818

Web:www.jsfiberwell.com   

Mail:alex@jsfiberwell.com

P.C.:224700  

Add: No.888 High-tech Hydraulic Technology Park, Center Road,

Jianhu, Yancheng, Jiangsu, P.R.C.

Jiangsu Fiber Composite Co., Ltd.  Nanjing Branch

Tel: +86 -025-86798609

MP +86-139-0518-7818

Web:www.jsfiberwell.com   

Mail:alex@jsfiberwell.com

P.C.:210012  

Add: Room G-712, Zendai Himalaya Centre, No 10 Minzhi Rd, Nanjing, Jiangsu, P.R.C.

language
中国
韩国
韩国
韩国
韩国
韩国